High
temperature heating without the need
for
oil and water |
 |
Digital microprocessor control
[PID] for highest accuracy |
 |
A variety of interchangable
insert blocks |
 |
Block combined with the close
fit of the tubes for fast efficient
heat transfer |
 |
Special thicker blocks guarantee
excellent temperature stability |
 |
Standard flat covers for protecting
the user from accidentally touching
a hot block and spitting tubes |
 |
Safety features :
Flashing alarm lamp to warn over-temperature
Over-temperature cut-out
Over temperature safety thermostat |
|
|
|
|
|
|
|
| Model |
ALB128 |
| Temp.range
|
Ambient
+ 5
~ 150 |
| Temp.Accuracy
|
0.5 |
| Heating
method |
Cartridge
Heater |
| Capacity |
2Block |
| Material |
Energy
plate and sample block : Aluminum
Inside and insulating
side : stainless steel |
| Weight |
7kg
(without block) |
| Dimensions
(mm) |
W238
D230
H155 |
| Wattage |
490W |
| Power |
AC110V
/ 220V / 230V, 50/60Hz |
| Unit |
| ALB128,
110V |
|
| ALB128,
220V |
|
| ALB128,
230V CE certificated. |
|
|
|
|
|
|
| Model |
Description |
|
Name |
Number |
| Block |
AB90-0.2 |
Block
/ 0.2ml centrifuge tube (90
90
H60)-capacity : 64ea |
| AB90-0.5 |
Block
/ 0.5ml centrifuge tube (90
90
H60)-capacity : 49ea |
| AB90-1.5 |
Block
/ 1.5ml centrifuge tube (90
90
H60)-capacity : 36ea |
| AB90-12 |
Block
/ 12
Test tube (90
90
H60)-capacity : 36ea |
| AB90-13 |
Block
/ 13
Test tube (90
90
H60)-capacity : 25ea |
| AB90-15 |
Block
/ 15
Test tube (90
90
H60)-capacity : 25ea |
| AB90-16.5 |
Block
/ 16.5
Test tube (90
90
H60)-capacity : 20ea |
| AB90-18 |
Block
/ 18
Test tube (90
90
H60)-capacity : 20ea |
| AB90-C15 |
Block
/ 15ml conical tube (90
90
H80)-capacity : 9ea |
| AB90-C50 |
Block
/ 50ml conical tube (90
90
H80)-capacity : 5ea |
| GB90 |
Ball
bath (zinc ball) |
| ALB128-MPL |
Block
plate / micro plate-capacity : 1ea
(for ALB128) |
Other
Accessories |
JD90 |
Block
extraction tool |
| CV128-80 |
High
cover for Test tube (W230
D115
H80mm ) |
|
| |
 |
 |
 |
 |
 |
| AB90-0.2 |
AB90-0.5 |
AB90-1.5 |
AB90-12 |
AB90-13 |
|
 |
 |
 |
 |
 |
| AB90-15 |
AB90-16.5 |
AB90-18 |
AB90-C15 |
AB90-C50 |
|
 |
 |
 |
 |
If
you order more
blocks than the
capacity of Unit. The
JD-90 would be included. |
| GB-90(Ball
bath) |
AB128-MPL
(For micro plate) |
JD-90 |
|
Cover |
|
|
|
|
 |
 |
|
|
|
| CV128-80 |
CV128-F |
|
|
|
|
|
|
|
|
|
|
|
|
 |
| |
|
| |
Company
: [435-862] 692-1, Guemjeong-dong, Gunpo-si, Gyenggi-do, korea
Post-Office Box : [158-600]
P.O.Box 100, Yang-Chun, Seoul, Korea
Tel : +82-31-429-7471~2 /
Fax
: +82-31-429-7470 / E-mail
: finepcr@finepcr.com |
 |
| |
|
|
|
 |
|